TOP Contributors

  1. MIKROE (2662 codes)
  2. Alcides Ramos (357 codes)
  3. Shawon Shahryiar (307 codes)
  4. jm_palomino (112 codes)
  5. Chisanga Mumba (90 codes)
  6. S P (73 codes)
  7. dany (71 codes)
  8. MikroBUS.NET Team (35 codes)
  9. NART SCHINACKOW (34 codes)
  10. Armstrong Subero (27 codes)

Most Downloaded

  1. Timer Calculator (137038 times)
  2. FAT32 Library (70167 times)
  3. Network Ethernet Library (56039 times)
  4. USB Device Library (46364 times)
  5. Network WiFi Library (41980 times)
  6. FT800 Library (41310 times)
  7. GSM click (29079 times)
  8. mikroSDK (26519 times)
  9. PID Library (26453 times)
  10. microSD click (25449 times)
Libstock prefers package manager

Package Manager

We strongly encourage users to use Package manager for sharing their code on Libstock website, because it boosts your efficiency and leaves the end user with no room for error. [more info]

< Back
mikroSDK Library

Pollution click

Rating:

0

Author: MIKROE

Last Updated: 2024-04-03

Package Version: 2.1.0.12

mikroSDK Library: 2.0.0.0

Category: Gas

Downloaded: 115 times

Not followed.

License: MIT license  

Pollution click carries the VOC gas sensor and has high sensitivity to organic gases such as methanal (also known as formaldehyde), benzene, alcohol, toluene, etc.

No Abuse Reported

Do you want to subscribe in order to receive notifications regarding "Pollution click" changes.

Do you want to unsubscribe in order to stop receiving notifications regarding "Pollution click" changes.

Do you want to report abuse regarding "Pollution click".

  • mikroSDK Library 1.0.0.0
  • Comments (0)

mikroSDK Library Blog


Pollution click

Pollution click carries the VOC gas sensor and has high sensitivity to organic gases such as methanal (also known as formaldehyde), benzene, alcohol, toluene, etc.

pollution_click.png

click Product page


Click library

  • Author : Mihajlo Djordjevic
  • Date : Dec 2019.
  • Type : ADC type

Software Support

We provide a library for the Pollution Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Pollution Click driver.

Standard key functions :

  • Config Object Initialization function.

    void pollution_cfg_setup ( pollution_cfg_t *cfg );

  • Initialization function.

    POLLUTION_RETVAL pollution_init ( pollution_t ctx, pollution_cfg_t cfg );

  • Click Default Configuration function.

    void pollution_default_cfg ( pollution_t *ctx );

Example key functions :

  • This function read ADC data.

    pollution_data_t pollution_generic_read ( pollution_t *ctx );

  • This function gets load voltage from read ADC value.

    float pollution_measure_load_voltage ( pollution_t *ctx, uint16_t adc_value );

  • This function gets the corrected resistance of the sensor.

    float pollution_get_corrected_resistance ( pollution_t *ctx, uint16_t adc_value );

Examples Description

Example code reads ADC value and measures quantity of organic gases in the air.

The demo application is composed of two sections :

Application Init

Application Init performs Logger and Click initialization.


void application_init ( void )
{
    log_cfg_t log_cfg;
    pollution_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_printf( &logger, "---------------------------------------------\r\n" );
    log_printf( &logger, "------------  Application  Init ------------\r\n" );
    Delay_ms ( 1000 );

    //  Click initialization.

    pollution_cfg_setup( &cfg );
    POLLUTION_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    pollution_init( &pollution, &cfg );

    log_printf( &logger, "---------------------------------------------\r\n" );
    log_printf( &logger, "-------------- Pollution Click --------------\r\n" );
    log_printf( &logger, "---------------------------------------------\r\n" );
    Delay_ms ( 1000 );

    pollution_default_cfg( &pollution );
    Delay_ms ( 1000 );

    log_printf( &logger, "------------ ADC Initializated ------------\r\n" );
    log_printf( &logger, "---------------------------------------------\r\n" );
    Delay_ms ( 1000 );
}

Application Task

This is an example which demonstrates the usage of Pollution Click board. Pollution Click reads ADC value, load voltage from ADC value, and reads
corrected resistance of the sensor where results are being sent to the UART terminal where you can track changes.


void application_task ( void )
{
    pollution_data_t tmp;

    tmp = pollution_generic_read( &pollution );
    log_printf( &logger, " ADC value : %d ppm\r\n\n", tmp );
    Delay_ms ( 1000 );

    value_volt = pollution_measure_load_voltage( &pollution, tmp );
    log_printf( &logger, " Load voltage : %0.2f V\r\n\n", value_volt );
    Delay_ms ( 1000 );

    value_res = pollution_get_corrected_resistance( &pollution, tmp );
    log_printf( &logger, " Corrected resistance : %0.2f kOhm\r\n\n", value_res );
    log_printf( &logger, "---------------------------------------------\r\n\n" );
    Delay_ms ( 1000 );
}  

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Pollution

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.


ALSO FROM THIS AUTHOR

AudioAmp 9 click

0

AudioAMP 9 Click is a compact add-on board reproducing input audio signals with desired volume and power levels at sound-producing output elements. This board features the PAM8124, a 10W efficient, Class-D audio power amplifier from Diodes Incorporated for driving stereo speakers in a single-ended configuration.

[Learn More]

3D Hall 9 click

0

3D Hall 9 Click is a compact add-on board used to detect the strength of a magnetic field in all three dimensions. This board features the ALS31300, a 3D linear Hall-effect sensor with digital output and advanced low power management from Allegro Microsystems. The ALS31300 features an I2C interface, enabling it to be easily configured by MCU with the measurement data provided in digital format of 12-bits corresponding to the magnetic field measured in each X, Y, and Z axes.

[Learn More]

Button G click

1

Button G click is the simplest solution for adding a single pushbutton to your design. The button itself is transparent, 6.8mm in diameter and has a green LED backlight. When pressed, it sends an interrupt signal to the target board microcontroller. The backlight LED is controlled separately through the mikroBUSâ„¢ PWM pin.

[Learn More]